STUDI METODE PENENTUAN NIFEDIPINE DENGAN TITRASI BEBAS AIR (NON AQUEOUS)

Abstract: The non-aqueous titration study using three types of samples. This study aims to determine the nifedipine  levels  contained  in  drugs  of  different  products  samples.  LOD  values  were  obtained sequentially  in  nifedin,  nifedipine  and  farmalat  is  0.0514;  0.0436  and  0.0532.  LOQ  value  in nifedin,  nifedipine  and  farmalat  is  0.1712;  0.1455  and  0.1772.  Values  of  the  correlation coefficients  obtained  in  a  strong  linearity  test  with  one-way  relationship.  Vallue  %recovery obtained at nifedin, nifedipine and farmalat is 100.06%; 98.75% to 100.9%. Levels obtained dried samples  ranged  from  1.53%  to  2.74%,  with  the  highest  contenst  in  nifedin  and  lower  in  the nifedipine (OGBdexa).
Keywords: Nifedipine, non-aqueous titration
Penulis: Jeany Buchermi, Yulizar Yusuf, dan Umiati Loekman