REDESAIN PERENCANAAN STRUKTUR HOTEL CITY ONE JALAN VETERAN SEMARANG
ABSTRACT: City One Hotel lies
at Veteran road, Semarang city. This hotel is built at less large area so
vehicle come in and sticking out floor basement becomes distress. This redesign
change distance between columns from 6 meters become 8 meters, so vehicle comes
in and sticking out floor basement become easier. Redesign of the Structure of
City One Hotel is make parking area more wider. Parking area from first design
only use 1st basement and 2nd basement, meanwhile result of redesign use 1st
basement, 2and basement and 2bth basement. First design of City One Hotel used
Double System with Intermediate Moment Resisting Frames (IMRF), meanwhile
redesign use Double System with Special Moment Resisting Frames (SMRF) for it
structure system. This redesign based SNI 1726-2012, and value of earthquake
parameter response was download from website of Ministry of Public Work for
Semarang City. In order to easier modelling and building structure analysis,
redesign of City One Hotel are helped by SAP.2000 version 12 and CSI Col
progam. The other differences between first design and redesign’s result is
cross-sectional shape of the column and sectional area of the beam. First
design use rectangular cross-sectional shape column, meanwhile redesign use
square cross-sectional shape column. Benefit of square cross-sectional shape
column is moment of inertia equally strong for both sides. The redesign’s beam
sectional area is wider than before, this is because increased load on beams
comparable with increasing distance between columns.
KEYWORDS: Double System with
special moment resisting frames; SNI 1726 2012, earthquake parameter response
from website of Ministry of Public Work
Penulis: Aldyan Wingga
Okiyarta, Fajar Nurjihad Cristian, Parang Sabdono, Windu Partono
Kode Jurnal: jptsipildd150136