PERANCANGAN STRUKTUR HOTEL AMARIS SIMPANG LIMA SEMARANG
ABSTRACT: Structural Design of
Amaris Hotel Simpang Lima Semarang designed with SNI 2847-2013 and SNI
1726-2012. Seismic analysis using dynamic respons spectrum method. Seismic
forces calculated based on area of the earthquake zone 4 as the region has a
fairly large earthquake acceleration, so it must be designed
earthquake-resistant structures. Included in Seismic Design Criteria Type D so
that the planning system used method with special moment resisting frames
system (SMRFS). Frame system is composed of a framework of beams and columns,
where the columns are made stronger than the beam (strong column weak beam). To
avoid failure of the structure at the beam-column joint, plastic form joint is
planned to occur in the beams and columns only occur at the top of the column
foundation. Structure analysis using anayisis structure program to help
modeling the structure and determine the forces acting on the structure.
Materials used are concrete f'c 25 MPa, where as for steel reinforcement plates
and stirrup fy 240 MPa and longitudinal bar fy 400 MPa.
Penulis: Ridwan Ruslan
Setiaji, Okky Nugroho Budiandono, Nuroji, Himawan Indarto
Kode Jurnal: jptsipildd150198