ABSTRACT: Bogasari Flour Mills
also used 8 Diesel Generator as Electrics Power Station. However only 2 of it
were actively used every day and the others were just standby. This paper
presents the distribution model of sound intensity generated by Diesel
Generators which were function of distance coordinate to listeners and constant
value of room acoustic. Based on sound intensity with 77 taking points on
variety of point and frequency, distribution number of intensity on each point
were modeled by using artificial nerve network model. Input model was distance
of taking point to Diese Generator number 5 and 6, while the output was sound
intensity on those points. Artificial nerve network model consisted of three
layers : first layer was input layer with 3 neuron cell, second layer was hidden
layer with 8 cell, and the third layer was output layer with 1 cell. From 200
epoch on network model, the model was obtained with 5,9% error average toward
the result of measurement.