ANALISIS KUALITAS LIMBAH CAIR PADA INSTALASI PENGOLAHAN LIMBAH CAIR (IPLC) RUMAH SAKIT UMUM LIUN KENDAGE TAHUNA TAHUN 2010
Abstrak: Hospital waste water
is one source of potential environmental
pollutant because it is necessary the management of waste water before it is
disposed in to public channels. This study is a descriptive analytic study, in
which the writer wanted to describe how
the quality of liquid waste in the RSU
Liun Kendage Tahuna, in
particular the parameters BOD, COD, TSS and
pH through laboratory tests. The
results of this study indicate that the average BOD eligible (28.6 mg /l) is smaller than the raw
waste water quality for hospital
activities that have been assigned
to 30 mg / l, the average COD is
not eligible (83.8 mg /l) exceeding
effluent quality standard of 80
mg / l, mean TSS is not eligible (31.3 mg /l)
exceeds the effluent quality standard of 30 mg /l and pH of the
eligible 6.6 to 7.8 with a value the average pH
= 7.1. The qualit of waste water effluent
discharged IPLC on the
urban public channel
after processing qualify
with levels of BOD
value = 7 mg / l,
COD = 25 mg / l, TSS =
11 mg / l and pH = 6.8.
To further improve the quality
of effluent RSU Liun
Kendage Tahuna, the need for
repair of damaged pipelines, periodic monitoring and
better management of
IPLC.
Penulis: Ferdy G. Pakasi
Kode Jurnal: jpkesmasdd110053