UNJUK KERJA SOLAR ASSISTED HEAT PUMP WATER HEATER DENGAN VARIASI REFRIGERAN CFC-12, HFC-134A DAN HCR-134A

Abstrak: An experimental study was conducted to determine the performance of a solar assisted heat pump water heater ( SAHPWH ). The system utilised flat unglazed aluminium collectors to absorb solar and ambient energy and used to evaporate  the  working  fluid.  The  system  was  tested  with  refrigerant  CFC-12, HFC-134a, and HCR-134a. Compressor was controlled by constant rotation. CFC-12 and HFC-134a admission based on working pressure  and HCR-134a 30% - 40% from weight CFC-12 or HFC-134a. Solar radiation was 600 W/m2 and water volume was 50 litre. Experimental results was indicated that HCR-134a has heat capacities,COP heat pump standart, COP actual was higher than CFC-12 and HFC-134a. The highest water temperature was produced by HCR-134a was 640C.  
Keywords: SAHPWH, HCR-134a, HFC-134a, CFC-12, COP
Penulis: Wibawa Endra Juwana