DETEKSI KERUSAKAN BANTALAN GELINDING PADA POMPA SENTRIFUGAL DENGAN ANALISIS SINYAL GETARAN

Abstract: The aim of the research was to detect the fault of rolling bearing in a centrifugal pump by vibration signal analysis. The investigation was focused on  the  frequencies  of  the  bearing  components,  that  are:  frequency  of  outer race, inner race, ball, dan cage. The pump with power 5,5 Hp and speed 1495 was  used  in  the  experiment.  The  vibration  data  was  obtain  by  piezeelectric accelerometer,  and  a  digital  storage  osciloscope.  The  MATLAB  software  then was  used  to  process  the  data  to  get  signal  spectrum.  Analysis  of  the  signal spectrum gaves that good condition rolling bearing have amplitude of 0,8 Volt. While, in defect ball bearings there were increases of amplitude in ball bearing components harmonic frequencies. The increase of amplitude were 1,2 Volt in 4 x Ball Pass Frequency of Inner Race (BPFI), 1,66 Volt in 3 x Ball Pass Frequency oh  Outer  Race  (BPFO),  and  2  Volt  in  2  x  Ball  Spin  Frequency  (BSF).  These increases of frequancies indicated the damage of the ball bearing components.  
Kata  kunci:  Centrifugal  pump,  rolling  bearing,  vibration  signal,  signal spectrum analysis
Penulis: Didik Djoko Susilo
Kode Jurnal: jptmesindd080023