PENGEMBANGAN TEKNIK REKONDISI TABUNG STORAGE CRYOGENIC UNTUK OPTIMALISASI PROGRAM INSEMINASI BUATAN (ARTIFICIAL INSEMINATION)

Abstract: Karanganyar district of Central Java as the one of cattle meat production has more  than  52,000  ox  popullation,  70%  cow  and  30%  ox.  However,  the breeders no longer use ox for breeding, meaning that almost 95% of breeding rely  artificial  insemination  techniques.  Important  equipment  and  the  most easily damaged IB is for cryogenic storage tank. Important equipment and the most easily damaged IB is for cryogenic storage tank. Need of liquid nitrogen storage tank reaches 65 unit with the level of damage to the 14 unit per year, and  not  have  a  workshop  that  is  capable  of  recondition  well.  Damage  from the  main  tube  is  tube  leak,  sponge  seal  leak  closed,  and  the  remaining includes  the  tube  broken  neck,  broken  canister,  hanger  dropouts.  The  main purpose of these activities is to develop recondition techniques and the tank so that  it  is  able  to  (1)  reduce  the  import  dependency  of  the  product  tanks,  (2) reduce the cost of artificial insemination, and (3) the self-help insemination by farmer.
Materials  research  is  a  tube  container  (cryogenic  storage  tanks)  that  have been damaged which is then reconditioned. Process improvements were made with  surgical  tubing,  then  determined  the  tools  used  in  the  tube  division, describes  its  components,  danselanjutnya  analyzed  the  materials  used  in  the tube. Next, the tube was reconditioned.
The results showed that the main damage on the tube is 30% leaky tube, 50% sponge  cover  seal  is  leaking,  and  the  remaining  20%  covering  broken  neck tube,  canister  broke,  broken  hanger.  Based  on  the  tests,  the  results  of reconditioning on tubes showed that  the  level  of  liquid  nitrogen leakage  will still occur but can be pressed up to the volume of nitrogen was 60% (period of a month).
Keywords: Artificial insemination, Cryogenic storage  tanks, Leaking  tubes, Reconditioning
Penulis: R. Hari Setyanto, Kuncoro Diharjo, Rusdjajanto