PENGARUH KETEBALAN INNER-HELICAL FIN TERHADAP CHARACTERISTIC OF PERFORMANCE PADA HEAD EXCHANGER

Abstract: Effect of inner-helical fin on the rate of heat transfer and flow friction factor in a double pipe heat exchanger (double tube heat exchanger) to make a split and disrupt the flow pattern of a streamlined flow of the fluid flowing in the pipe section in the (inner tube) that cause turbulence (molecule-molecule level of randomness good fluid) that can increase the heat transfer ratein the the pipe . Inner-helical fin has a varied thickness of 1 mm, 22 mm and 3 mm are mounted on the pipe where the inside diameter of the inner-helical fin attached to the wall in the inner pipe. Hot  water  discharge  on  the  inner  pipe  ditelitil  ranging  from  400  to  900  liters  /  h  with  interval increase in 100 liter / hour and the volumetric flow rate of cold water on the outer tube (outer tube)  is  kept  constant  900  liters  /  hour.  The  test  results  of  each  inner-helical  fin  thickness compared with the test results without the inner-helical fin (plain tube) and obtained the overall heat transfer rate has increased 60 to 65% of the plain tube, heat exchanger effectiveness of 58.56 to 63, 64% and friction factor of 63.13 to 63.51 of the plain tube.
Keywords: Inner-helical fin, Heat exchanger, rate of heat transfer, friction factor
Penulis: Ishak Usman, Slamet Wahyudi, Bambang Dwi Argo
Kode Jurnal: jptmesindd100179