PENGARUH UKURAN DIAMETER PIPA OUTLET FOAM GENERATOR TERHADAP KUAT TEKAN DAN SERAPAN AIR BATA RINGAN JENIS CLC
Abstract: The power of
Cellular Lightweight Concrete is influenced by the size of its pores. If the
Lightweight Concrete’s pore is larger, then the compressive strength is smaller
and the uptake of water produced is greater. This is caused by the using of the
outlet pipe diameter that is greater cause cavities in the foam produced even
greater. That foam occupy cubes of concrete’ space and generate pores that are
large on the Lightweight Concrete, causing its compressive strength are small
and water’s absorption is large if it is compared to the diameter of the outlet
pipe is smaller. The test results in the laboratory is the compressive strength
of Cellular Lightweight Concrete in 14 days amounted to 2.148 MPa, 2.074 MPa,
1.926 MPa and 1.852 MPa on the variation of ½ inch, 1 inch, 1 ½ inch and 2
inches diameter. In 28 days, it amounted to 2,667 MPa, 2,593 MPa, 2,444 MPa,
dan 2,296 MPa with same diameters. In 42 days, it amounted to 2,815 MPa, 2,667
MPa, 2, 519 MPa, dan 2,444 MPa on diameter of 0,5 inch, 1 inch, 1,5 inch, and 2
inches. In 56 days, it amounted to 2,889 MPa, 2,741 MPa, 2,593 MPa, and 2,519
MPa with same diameters. At the age of 56 days, the average value of water
absorption of the CLC with outlet foam generator of diameter of 0.5 inches
amounted to 13.554%. Whereas on 1-inch increase to 15.268%. The size of 1.5
inches increased to 17.163% and the size of 2 ins by 19.463%.
Keywords: Bata ringan Cellular
Lightweight Concrete (CLC); diameter pipa; kuat tekan; serapan air; Cellular
Lightweight Concrete (CLC); diameter pipe; compressive strength; water
absorption