PERENCANAAN STRUKTUR GEDUNG RADIOTERAPY DAN ONKOLOGY CENTRE RSUP DR. KARIADI SEMARANG
ABSTRACT: Structural design of
buildings Hospital Radiotherapy and Oncology Centre of Public Hospital Dr.
Kariadi Semarang, refers to three standards: (1) minimum loads for buildings
(SNI 1727-2013), (2) Earthquake resistance standard for buildings (SNI
1726-2013), and (3) standard of concrete for structural buildings (SNI
2847-2013). This building design is categorised as Building Risk IV, which has
value factor virtue of earthquake (Ie) about 1.5 and located on the medium soil
types. The Earthquake loads analysis of this building using the spectrum
response. Based upon the seismic criteria, this building is included as
Building Type D with high risk of seismic level. Therefore, the building design
uses Special Moment Resisting Frame System (SMRFS) to reach the greater
performance of column capacity upon the beam or Strong Column Weak Beam. These
conditions require the beam-column joint should be well designed in order to
avoid collapse when the beams are undergoing plastic hinge. The depth of the
hard ground at the site of implementation is 4 m and 9 m, type of land included
in the category of land under. The location is adjacent with the existing
building, so for minimize the vibration of pile foundation erection used size
(30 x 30) cm.
Penulis: Tintus Triubekti,
Anindita Hapsari, Himawan Indarto, Muhrozi
Kode Jurnal: jptsipildd160249