PERANCANGAN STRUKTUR HOTEL IBIS BUDGET SEMARANG
ABSTRACT: Structural Design of
Ibis Budget Hotel Semarang was designed to comply with SNI 2847-2013 and SNI
1726-2012. Seismic analysis was conducted using dynamic respons spectrum
method. The building was designed to be located in zone 4 Indonesian seismic
vurnability map meaning that it can experience large earthquake acceleration.
Hence the building must be designed as an earthquake-resistant structures. This
building was designed as special moment resisting frame systems (SMRFS). The
frame system was composed of beams and columns. The columns were designed to be
stronger than the beams (strong column-weak beam concept). The concrete was of
f'c 29,05 MPa, and the steel reinforcement of the longitudinal bar was fy 400
MPa. The Structure analysis was conducted using an analysis structure program
to model the structure and calculate the internal forces on the structure.
Failure at the beam-column joint was avoided by designing plastic hinges to
occur at the beam ends and at the top base columns connected to foundation.
Penulis: Wirajati Ramadhianto,
Novia Puspitarini, Ilham Nurhuda, Nuroji
Kode Jurnal: jptsipildd160238