PENGARUH KEVAKUMAN TERHADAP EFEKTIVITAS KONDENSOR PLTU BARRU UNIT 1
ABSTRACT: The condenser is one
of the important equipment in a power plant in the process, especially at the
power plant system whose function is to condense the exhaust steam turbine
extraction into water droplets (condensate water) which is then circulated back
to boiler reprocessed into steam. Vacuum condenser is one of the parameters
that influence the effectiveness and efficiency of the condenser in particular
plants in general. This final report aims to determine the effectiveness of the
condenser based on actual data, the optimal gain vacuum value, and comparison
between the specifications and the actual effectiveness of the condenser. The
method used is collecting data on the load condition of 50%, 75%, and 100% and
then perform data analysis.Results will be presented in tables and graphs then
making a conclusion. Based on the data and analysis that has been done, it is
known condenser effectiveness decreases with an increase in vacuum pressure.
Optimum vacuum level is on a scale (80) Kpa - (85) Kpa. From the analysis of
the data also can be seen that the effectiveness of the actual data is higher
than the effectiveness of the data specification.
Keywords: Efektiveness,
Condensor, Vacuum
Penulis: Apollo, Musrady
Mulyadi, Achmad Yoga Issaniyah, Fefrianto Muh. Surahman
Kode Jurnal: jptmesindd140443