ABSTRACT: Poor supervision in
the project execution can cause a mediocre performance of construction quality,
including concrete quality. Structural Strength Evaluation on the seven stories
building, building H of Dian Nuswantoro University has demonstrated the impacts
of poor performance of these concrete qualities. The concrete quality have been
designed by K250, ,and decrease to K150 because of that poor supervision from
level 1 to 3. The function of first three levels are supporting four stories
above by concrete quality K300.The impact evaluation of different concrete
quality on the building H is undertaken by comparative assessment throughout
three SNI, they are SNI 03-1726-2012, SNI 03-2847-2013, and SNI 1727-2013.Structural
evaluation is undertaken by three dimensional simulation method from the field
data information. Based upon the structural simulation, therefore the main
structure need a strengthening to support the service load of the building H.
The result of structural analysis due to the standard found that some of beam
elements need a strengthening by enlarging section area and increasing
reinforcement ratio of the column.