Analysis of Rewetting Time and Temperature Distributions During Cooling Process in Vertical Rectangular Narrow Channel
Abstract: Cooling process
to analyze effect
of gap size
to rewetting time
and temperature distributions were studied
from transient temperature
of surface plate. It
as result of
experiment using two vertical
plate with the initial
temperature about 600°C. Debit and temperature of
cooling water are 0,09 L/s and
saturated temperature. The gap sizes were changed from 1 mm, 2 mm, and 3 mm. As
the results showed that the smaller the gap size, the longer the rewetting
time. Pattern of temperature distribution is similar at initial condition for all of gap
sizes and the smaller the gap sizes, the longer the time of decreasing
temperature.
Author: IGN. Bagus
Catrawedarma, Indarto, Mulya Juarsa
Journal Code: jptmesingg130003