Analysis of Rewetting Time and Temperature Distributions During Cooling Process in Vertical Rectangular Narrow Channel

Abstract: Cooling  process  to  analyze  effect  of  gap  size  to  rewetting  time  and  temperature  distributions were  studied  from  transient  temperature  of  surface  plate. It  as  result  of  experiment  using  two vertical  plate  with the  initial  temperature  about 600°C. Debit  and temperature  of  cooling  water are 0,09 L/s and saturated temperature. The gap sizes were changed from 1 mm, 2 mm, and 3 mm. As the results showed that the smaller the gap size, the longer the rewetting time.  Pattern of temperature  distribution is  similar at initial condition for all of gap sizes and the smaller the gap sizes, the longer the time of decreasing temperature.
Keywords: Cooling process, rewetting time, temperature distribution
Author: IGN. Bagus Catrawedarma, Indarto, Mulya Juarsa