STUDI EFEK KERR UNTUK PENGUJIAN TINGKAT KEMURNIAN AQUADES, AIR PAM DAN AIR SUMUR
ABSTRACT: In this
research was discussed
about the ratio of
purity level of
aquades, running water,
and well water by
using the Kerr
effect. Several substances
being used are
sugar solutions with the concentration of
10%, 20%, 30%,
40% and 50%
for linearity testing, salt
solutions with the concentration of
10%, 30% and
50% for the testing
of ionic response
which be infested
by some dipoles of
H2O molecules in the salt
solution toward the external
electrical field, and
also aquades, running water and
well water as the water samples having the different purity. The external
electrical field being given
in the substances from zero
to 9×105V/m and
awakened by conducting
the direct current of electric on
the parallel plates. A light
beam being used is a diode laser with
λ= 645 nm. The result of research was showing that the presence of
external electrical field causing the difference of polarization angle indicating the purity level of water kinds
since influenced by ions in the water. Based
on the ions
containing in it have been
known that the
value of aquades
purity is 4
ppm, he value of running water
purity is 108 ppm and the value of well water purity is 190 ppm. So, aquades is
purer than running
water and running
water is purer
than well water.
The average value
of polarization angle of aquades, running water, and well water is
approximately 0,50º, 0.25º and -0,25º respectively.
Penulis: Kristantyo Sukarsono,
Indras Marhaendrajaya, K. Sofjan Firdausi
Kode Jurnal: jpfisikadd080033