Pengamatan Efek Magnetooptis Menggunakan Interferometer Michelson
ABSTRACT: The magnetooptic
effect of transparency
material such as
aquarium glass, acrylic,
and micro slide has been studied using Michelson Interferometer. The
change of refractive index to magnetic field B is obtained
by placement of
samples in a
coil applied on altered
field 0-0,2 T. Results
of interferometer test show that change of refractive index is
linearly dependent on B for acrylic and slide. However, for aquarium glass, it
is on B2dependency. This result is agreement to previous experiment that the
structure of acrylic and slide is formed more regular as B applied.
Penulis: Fahrurazi,
K. Sofjan Firdausi, Wahyu Setia Budi
Kode Jurnal: jpmatematikadd060004