PENGUJIAN KARAKTERISTIK PERPINDAHAN PANAS DAN FAKTOR GESEKAN PADA PENUKAR KALOR PIPA KONSENTRIK SALURAN ANNULAR DENGAN TWISTED TAPE INSERT WITH OBLIQUE TEETH

Abstract: This  research was conducted to examine  the characteristics  of heat  transferand friction factor in the  annular  channel  concentric  tube  heat  exchangerwith the addition of twisted tape insert with oblique teeth. Test section was the single  pass  concentric  tube  heat  exchanger  with  inner  tube  and  outer  tube made  of  aluminum.  The  length  of  heat  exchanger was  2,110  mm  and  the length of pressure  drop measurement in  the inner  tube was 2,240 mm. Flows in the inner tube and in annulus were counter flow. Working fluid in the inner tube  was  hot  water  which  its  inlet  temperature  was  maintained  at  60°C, whereas  the  working  fluid  in  the  annulus  was  cold  water  with  its  inlet temperature of ± 28oC. For comparison, inner tube tested without twisted tape insert (plain tube) and with the addition of twisted tape insert without oblique teeth (classic twisted tape insert). Classic twisted tape insert and twisted tape insert with oblique teeth  made  of aluminum strip with a thickness  of 0.7 mm, width 12.6 mm, which had a twist ratio of 4.0 and the pitch length of 50.3 mm. While  the twisted  tape  inserts  with  oblique  teeth  varied  with  tooth  angle  of 15°,  30°  and  45°.  Classic  twisted  tape  insert  and  twisted  tape  inserts  with oblique teeth installed in the inner tube of the concentric tube heat exchanger. The research result has showed that the inner tube with the addition of twisted tape  insert  with  oblique  teeth  produce  Nusselt  number,  friction  factor  and thermal performance that was greater than the addition of classic twisted tape insert  and  plain  tube.  Values  of  Nusselt  number,  friction  factor  and  thermal performance increase with the increase in tooth angle  of twisted tape inserts with  the  oblique teeth. At  the  same Reynolds number,  the  addition  of twisted tape insert with oblique teeth with a tooth angle 15°, 30°, and 45° resulting in an increased average Nusselt number in the inner tube, of 61.8%, 75.3% and 89.2%  when  compared  to  the  plain  tube,  respectively.  Compared  to  classic twisted  tape  inserts,  inner  tube  with  twisted  tape  inserts  with  oblique  teeth with  a  tooth  angle  15°,  30°,  and  45°  experienced  increase  Nusselt  numbers, an  average  of  10.2%,  19.4%  and  28.9%,  respectively.  At  the  same  Reynolds number, the addition of classic twisted tape insert and twisted tape insert with oblique  teeth  with  a  tooth  angle  15°,  30°,  and  45°  in the  inner  tube  has produced  an  average  friction  factor  of  2.4;  2.9;  3.4;  and  3.9  times  than  the friction  factor  of  plain  tube,  respectively.  The  average  thermal  performance with  the  addition  of  classic  twisted  tape  inserts,  twisted  tape  inserts  with oblique teeth with a tooth angle 15°, 30°, and 45° in the inner tube of 1.003; 1.060; 1.106; and 1.151 respectively.
Keywords:  Nusselt number, Reynolds number, Twisted  tape  insert  with, oblique teeth, Tooth angle
Penulis: Mirando Eka Wicaksono, Tri Istanto, Wibawa Endra Juwana
Kode Jurnal: jptmesindd120012

Artikel Terkait :