PENGUJIAN KARAKTERISTIK PERPINDAHAN PANAS DAN FAKTOR GESEKAN PADA PENUKAR KALOR PIPA KONSENTRIK DENGAN SISIPAN PITA TERPILIN BERLUBANG

Abstract: This research was conducted to examine the characteristics of heat transfer and  friction  factor  in  the  annular  channel  concentric  tube  heat  exchanger with  a  classic  twisted  tape  insert  and  perforated  twisted  tape  inserts.  Test section was the  single pass concentric tube heat exchanger with inner tube and outer tube made of aluminum. Dimensions of outer tube; outer diameter of 21.87 mm and inner diameter of 20.67 mm, and dimensions of inner tube, outer diameter of 15.84 mm and inner diameter of 14.34 mm. The length of heat exchanger was 2,000 mm and the length of pressure drop measurement in the inner tube was 2,010 mm. Flows in the inner  tube and in annulus was counter flow.  Working fluid in the inner tube  was hot  water which its inlet temperature was maintained at 60°C, whereas in the  annulus was cold water at 28oC. Both of classic twisted tape insert and perforated twisted tape insert with  a  twist  ratio of  4.0  were  made  of  aluminum  strips  with  a thickness  of 0.76 mm and width of 12.61 mm which it was twisted  so forming twist with the length of pitch was 50.35 mm. Perforated twisted tape inserts were varied with  holes  diameter  of  4  mm  and 6.5  mm,  respectively,  where  the  distance between  the  center holes of 4 cm. Twisted tape insert installed in the inner tube  of  the  concentric  tube  heat  exchanger.  The  results  showed  that  at  the same  Reynolds  number,  the  addition  of  classic  twisted  tape  insert  and perforated twisted tape insert with holes diameter of 4 mm and 6,5 mm in the inner tube increasing the average Nusselt numbers w ere 79,20%, 68,7%, and 57,8%   than  the  inner  tube  without  a  twisted  tape  insert  (plain  tube), respectively. At the same pumping power, the average Nusselt number in the inner  tube  with  the  addition  of  perforated  twisted  tape  inserts  with  holes diameter of 6.5 decreased 1.62%, whereas the addition of perforated twisted tape  inserts  with  holes  diameter  of  4  mm  classic  tw isted  tape  inserts increased the average Nusselt number were 3.2% and  5,84% compared with plain tube, respectively. At the same Reynolds number, the addition of classic twisted tape inserts and perforated twisted tape insert with holes diameter of 4  mm  and  6,5  mm  in  the  inner  tube  increased  the  average  friction  factor 339.25%,  298.49%  and  269.6%  than  plain  tube,  respectively.  At  the  same pumping  power,  the  addition  of  classic  twisted  tape inserts  and  perforated twisted  tape  insert  with  holes  diameter  of  4  mm  and 6.5 mm  in  inner  tube increased the average friction factor 485.39%, 416.48 % and 362.72% than plain tube, respectively.
Keywords: Nusselt number, Reynolds number, friction factor, perforated twisted tape insert
Penulis: Tri Istanto, Wibawa Endra Juwana
Kode Jurnal: jptmesindd110019

Artikel Terkait :